Modaris V6R1 and Diamino V5R3 is pattern maker software which is a package which is run with both windows 7 and windows xp. There are different version of VigiPrint is found in market. You can install all version and test which is the best version for you. If you research with all version than you will get the best solutions for your customer. Modaris 7 and diamino 5 is a package which is run with windows 7 only VigiPrintV2R4c18 Installation Process. We need to Install I Manager Software. We sale all types of Garment and Textile ERP Software in bangladesh at cheapest price.
HPGL conversion with Just print and VigiPrint. VigiPrint up to 6 default . VigiPrint updated for Lectra 7 and Lectra 6. VigiPrintV2R4c18 installation process is very essay. We are showing below how to install Vigiprint V2R4:
At first open the Software folder. Then click the exe file of VigiPrintV2R4c18. Then click Next. Then click Next. Then click Install. Then click Finish. Now Restart your computer.
VigiPrint Setting for Marker and Pattern
We need to create marker icon and marker module . First Double Click VigiPrint Icon from desktop. Now we are showing in detail how to configure vigiprint pattern maker software for Marker making and marker print below –
Library Access Icon for Marker
At first click Library Access Icon. You will get a from here. The form name is Data Location. Here you can change data location. Then go to marker info text box . Double click in this text box. Here you will and Click combo box for select marker option from this path – C:\Lectra\TextLib\Marker.Lab. Then click up arrow and down arrow for select all text box. After selecting Marker.Lab click OK. After that click Save Icon.
Library Access Icon for Pattern
This is very similar to marker setting. For pattern section go to Marker info text box . Double click here and Just select Pattern instead of Marker . e.g. C:\Lectra\TextLib\Pattern.Lab. Click Down Arrow to slect all. After that click Save Icon.
Save Parameter Icon for Marker
At last you need to click Save Icon. You have to click this icon whenever you will change something.
Save Parameter Icon for Pattern
Same as Marker setting.
Text Parameter Modification for Marker
You need to select some option under this icon. First click on check Part Info and check it. Then click and checked Vectoriel Font. Then make font size 12 because 12 is standard size. You can change fonts name form here also. Please select gb fonts. You can change your requirements. It is optional. You need to click icon (Bit information Layout) right sight of part info and you can change the variable according to your requirements. After that check Heading. After clicking check box of Heading you can change variable of the icon (Heading definition). Heading definition is located right sight of Heading. In Heading definition icon please hold the shift key and select Marker name, Length, Width, Date, Efficiency, Comments etc. Then click OK button. After setting all parameter under Text Parameter modification, don’t forget to click Save Icon. After that check Special Text. Then click OK. And click Save Icon.
Text Parameter modification for Pattern
Text Format Icon for Marker
Now click Text format. Here select Apparel and PLX, IBA. After that click Ok. And after that click Save Icon.
Text Format Icon for Pattern
It is very similar to Marker setting.
Machine Parameters Icon for Marker
By default there is no setting job in machine parameter function
Machine Parameters Icon for Pattern
This is very similar to marker
Geometry parameters modifications icon for Marker
From Geometry parameters modifications icon please select Grain line, Contour, T4, T7, T8, Blocking. In the icon of Blocking right sight make white line. Ensure white line icon of Grain line. Ensue Left arrow of Grain line. Mark Tools – All selected. Notches – All selected. That means select T2, T3, T5, T35, T36, Mofif etc from right sight. Then click OK. And click Save Icon.
Geometry parameters modifications icon for Pattern
This is also very similar to Marker setting.
Operating Icon for Marker
There is no setting in Operating Icon by default. You can change variable of Gap between marker, Splice mark, Common lines, Folded fabric, Transversal cut parameter, Frame etc. After that click OK. And click Save Icon.
Operating Icon for Pattern
Very similar to marker setting
Lock Icon for Marker and Pattern
Never Lock VigiPrint. If VigiPrint is locked accidentally than it must need to be uninstalled.
Garments Input module for Pattern
Double click Model Text Box. Select .mdl pattern file. Now change size No Nest to Complete Nest. After that click Add Command button. As a result the pattern file name will show in big text box of left sight of Vigiprint main window. Now click Send order button.
When you click send order button it will prompt you. And give you a message ” Please confirm the sending of the order. “ Then click OK. As a result the file will be stored in pattern folder. The file name will be (null).hpg. Change (null).hpg into desired file name.hpgl. Open desired file name.hpgl file with HPGL software and print it.
How to Open a Marker File
At first open vigiprint pattern maker software. Then double click Marker File Text box, Then select the marker file from the folder. Then select file type *.PLX. Then click Down arrow to select all option same. e.g. Marker Lib, Model Lib, Part Lib will be similar to Marker file text box. Then click Add Button. Now click Send order button. Now it will prompt you and give you a message “ Please confirm the sending of the order” Then click OK button. Now go to E:\Marker folder . Finally it will create a file under Marker folder named as (null).hpg. You need to rename the file (null).hpgl. Open the (null).hpgl with HPGL software and vigiprint pattern maker software and print your file.
Engr. Kh. Mashiur Rahman, Garments Auto Machine Technologist
I Manager Software is used for Lectra Plotter setting and for HPGL viewer. If you install I manager than you will get plotter list in start menu otherwise you don’t get this menu. I manager is used for printer creation. Please remember, Imanager is very sensitive. If you do any wrong configuration than your will face trouble again and again. to overcome it you will need to setup windows again and install again I manager freshly. If you don’t go for formant than you can configure in different profile. If you configure it in separate profile than you need not to setup windows again. Below we are showing how to configure Plotter for marker, pattern and mini printer with the help of I manager. We are sole agent of all Garment and Textile ERP Software companies. We will forward you to the best ERP software company based on your requirements. We are trouble shooter of fashion industrial software like Willcom, Barudan, Lectra, Gerber, iEcho, Datacolor, Shedomaster, Batch, Qc etc
First Click Start Button –Then click All Program – Then click Lectra– Then click IManager– Then click LectraPlotter List – Than click File– Than create New Plotter– Then HPGL Generator from combo box- Then click Next– Then assign printer name/ peripheral name – Then select default for Yes or no option button- Then click next button – Then click next button- Then click Plot test button –Then HPGL Generate directly. Now you need to create same name of assign printer name/ peripheral name in any drive of your computer. If you want to print mini print for buyer than select Windows printer instead of HPGL Generate directly – Then click OK– Then click Finish
We should install three plotter stated below-
Marker
Lectra Plotter
Miniprint
Setting and Format Change
First Click Start Button –Then click All Program – Then click Lectra– Then click IManager– Then click again IManager for setting and format change. If you click format button than you can change the page setting and other setting. After setting paper type click Ok button to fix it.
TextLib Configuration for Lectra Plotter
MARKER.LAB, PATERN.LAB, TEXT.LAB should be crated previously. There is some rules to create this 3 .LAB file. We will show you, how to create this types of files. Now we are showing the configuration path of MARKER.LAB, PATERN.LAB, TEXT.LAB in C directory below.
First go to C drive. Then go to Lectra Folder. Then go to TextLib Folder. From Here MARKER.LAB, PATERN.LAB, TEXT.LAB etc should be preserved for future use.
A professional vinyl cutter also needs an easy and professional vinyl cutting software. Easy Cut Studio is the ultimate All-in-One software to designing, drawing, print and cut all things vinyl. designed for great performance and to support all Vicsign cutters, With the user-friendly interface, users can add the registration marks, and cut images with ease. You can read more about
Vicsign cutting plotter software use true USB2.0 high speed data transmission: No need to install USB drivers, Support USB Virtual Interface Converter. High-precision digital servo DC: High-precision output, lower noise less than 50dB at work. Multi-output interfaces: RS-232C / USB2.0 /SD Card(1-8G)/U Disk. Higher cutting force, 1200g pressure suits for strong strength reflective film and various coated materials within 1mnn. Intelligent & automatic contour cutting function: Automatically scan in a row, Safety precautions
Vicsign Cutting Plotter Specification
Technical Parameter
Value
Name
Vicsign cutting plotter software
Model
HSQ1200/1080/630
Structure
Drum type
CPU
32-bit
Driver
Digital Servo motor
Positioning Mode
Precision electronic Bounded System, random original
Max Paper Feed Width
1300/1180/730mm
Max Cutting Width
1200/1080/630mm
Max Cutting Speed
1200mm/s
Cutting Force
0-1000g(Digital adjustment)
Mechanical Precision
0.05mm
Repeatable Precision
<± 0.1mnn
Workable Pen Number
1 pen
Interfaces
RS-232C/USB2.0/SD ( 1-8G ) /U Disk
Cache Memory
8MB
Programming resolution
DM-PL:0.1/0.05/0.025/0.01mm; HP-GL*2:0.025mm
Cutting mode
Intelligent&automatic contour cutting
Display panel
LCD
Power Supply
AC110V/220V± 10% 50Hz/60Hz
Power Consumption
50w
Operation Environment
10°C – 35°C/35% 75%RH
Workable Environment
16t – 32°C/35% – 75%RH
Noise at work
50dB
External Dimension
1562x342x385/1442x342x385/982x342x385
Shipping Weight
35kg/33kg/25kg
Features of Vicsign Cutting Plotter
No leaking any liquid into plotter
Don’t touch top of cutting blade
Use power cable correctly, no bend.
No lean.
Don’t use plotter when thundering
Standard accessory
Assemble cutting plotter:
3.1 1200mm&1600mm plotters have stand, stand is optional for 630mm,330mm plotters has no stand. First lock stand with screws; Put the vicsign cutting plotter in a dry and flat place, connect power supply, USB cable;
3.2 Install cutting blade as below:
3.3 Place the materials in cutting plotter, the steel shaft claw should be fixed on the roller as photo shows:
3.4 Buttons:
Off line pause: Offline the cutting plotter, can move the carriage; Pause the cutting plotter when it is cutting;
Origin: Fix the place.
Test: Before cutting, do a test to confirm the blade is installed correctly, the force and speed is suitable for materials;
Mode: Exchange Chinese to English, change blade to pen;
Reset: Reset the files;
Enter: When using SD card to cut, find the exact file, click “Enter” to start cutting;
Direction key buttons: LCD shows speed and force, up and down buttons, increase or decrease speed, left and right buttons change force; Offline cutting plotter, move carriage with direction key buttons;
Force and speed:
Cut some thin materials like vinyl, the force will be around 100g,cut thick materials like reflective film, it is about 200g-300g;The speed for step motor vicsign cutting plotter is 0-650mm/s, servo motor cutting plotter is 1200mm/s;
4. Install USB driver
USB driver is optional to install.When install USB diver via USB cable, and the system of computer is 32-bit Win xp/Win7/Win8,should install 32-bit USB driver ; the system of computer is 64-bit Win7/Win8, should install 64-bit USB driver. When the plotter works without USB driver , should choose “USB_Printer_0” as port in Flexi software. But select “USB001” as port in Coreldraw plug-in. (Use RS232 cable, no need install USB driver, and the port will be COM1) Print the file, no enlarger or smaller than original file, proportion is 1:1(100%): Place the image in vicsign cutting plotter click “offline pause” button, move the carriage and fix the blade/pen in the area of Mark1, then click “origin” We sale all types of RMG software all over the world including Bangladesh.
The Lectra vigiprint apparel software is the product of lectra kaledo is used for inputing & managing plotting files batches intended for a group of plotters, printers & small Lectra laser cutters that is interlinked to the station by an Ethernet netjob. These marker plotting files design are approved out as general task. The Lectra vigiprint marker print software is configurable generally at installation for processing several file type according to their file format . The files of Lectra vigiprint are generally formed by apparel industry, Upholstery, Footwear or Industry Lectra CAD – COMPUTER AIDED DESIGN software. For apparel Lectra vigiprint can process files produced by the LS Type & Modaris applications. It cutfiles created by non-Lectra CAD – COMPUTER AIDED DESIGN
We are the largest Garment and Textile ERP software collector in Bangladesh. We sale customized ERP for the factories. We are agent of all Garment and Textile ERP Software company. We will forward you to the best ERP software company based on your requirements. We are trouble shooter of fashion industrial software like Willcom, Barudan, Lectra, Installation process of Lectra Plotter I Manager Software, Gerber, iEcho, Datacolor, Shedomaster, Batch, Qc etc. Email: autogarments@gmail.com, Cell: +88 017 92 52 53 54
The Lectra vigiprint software proposes have two use levels :
The level for a current use – input batches as well as launch the plotting files & follow-up the plotting files
The Master level also enables management of the job & configuration parameter & it gives access into the plotter control.
This module of VigiPrint software for graphtec plotter can be operated on a general PC type job station with a Linux operating system, derived from UNIX for the PC. This station integrates the open partner graphic desk
Graphtec PlotterSoftware installation:
The Lectra vigiprint package of graphtec plotter need to be installed by the P Manager value according to the process explained in the document. When opening Lectra vigiprint for the very first time on the job station the default configuration files are created randomly and automatically. This TRAPARAM FORMATEDfile system can be modified later.
Launching the Software for Graphtec Plotter:
When the installation, configuration & starting procedures of graphtec plotter of the environment have been finished this print software is presents from the Open Partner graphic station. In the applications area double click the icon representing Lectra vigiprint. During the software loading time it show an information dialogue box which is viewed then the main software screen of Lectra vigiprint is viewed.
Quitting the software:
For quitting the print software use the Quit function icon in the bottom left corner of the main software screen. Generally Click on Quit icon button of the software proposes a Confirmation dialogue box with a YES button & a NO button. It is also imaginable to quit the software by using the Quit icon. This printing software is used to print marker of lectra diamino software.
Operating Principles of Cad Plotter Software:
The many job stations of CAD – Computer Aided Design plotter & the plotting files or cutting peripherals are interlinked by an Ethernet netjob. The utility of the applications group Administrator Utilities is used normally to declare the peripherals acknowledged ment by each station on the network. In the example shown below the station on which Lectra vigiprint has been installed only acknowledges Plotter 1 as well as Laser cutter 1. These two process only will appear in the list of plotters that can be selected. The Lectra vigiprint software are capable to plot files from various environments. For example Apparel Industry, Upholstery Industry, Footwear Industry & Industry or non Lectra kaledo CAD – COMPUTER AIDED DESIGN Plotter. For apparel industry the Lectra vigiprint can process the files whose shapes are produced by LS Type only , the Modaris only or either one of them. These various possibilities are determined by the input formats that is available for Lectra vigiprint. Generally they are chosen when installing the software, but they should be modified later at Master level
The main determination of Lectra vigiprint CAD – Computer Aided Design plotter software contains in inputting a file or a list of files to be plotted. Once sent into the plotter, the file becomes a batch. The operations corresponding of this task are explained in the system. When one or several batche has been sent into the plotter the operator can visualize to modify these batches. To define or carry out a plot a certain number of information are called parameters are requested. This information is related to the plotter & stored it in a TRAPARAM FORMATED file. This types of file created automatically at the first use, contains default values. The operator can define his own values to keep them for another job station to save them in the TRAPARAM FORMATEDfile. At last the operator may intervene directly on the plotter from the job station to switch it on or off reset to zero, access the maintenance mode.
Selecting a Plotter for Plotter Service:
This function & plotter service is using for selecting the main garment plotter where the batches must be plotted. As a default value the name of the last plotter is selected is viewed in an input area of the main software screen. After double clicking on this input area it will display a dialogue box Selecting a plotter
After that to select a plotter choose any name from the list then close the selection with button to get plotter service. Generally the name of the selected plotter is viewed in the main software screen. When select a plotter name the locations of the files by default associated to this plotter are viewed automatically as the input grid. The default value of the plotter related to this plotter are automatically allocated to the library, text, geometry & operating parameters of plotter service.
Adding a Line is Plotter Service:
In this function is used for adding a line in the list of files to be plotted by indicating a file name & its associated plotting files parameters.
When there is no line selected in the list the input area for the file name in the grid is empty.
Modify & complete if required the plotting files 0attributes showed in the input grid
Input the name of the file that need for plotting in the input area
Validate the line addition by clicking on add button
The name of the file need for plotting is erased in the input area,
The plotting files parameters are not modified that makes possible to input several lines in a row with the same parameters.
Description of the plotting attributes
Modification in the input grid : Two parameter lines are normally used to define the name and location of the file to be plotted :
Input zone 1 is used for indicating the name of the file to be plotted, and input zone 2 the location of this file with the usual syntax directory1/directory2 / … /directoryN
For modifying the contents of an input zone, the user can either input directly the access path or the file name. For this double click on the input zone, to open the selector.
The Push Button is used to copy the location of the markers or the garments into the form.
Modification in the work list : The name of the file to be plotted is recalled under the Marker , Garmentor Part icon depending on the active input mode.
Vigiprint of Lectra Kaledo Linked to the work Configuration:
For Plotting parts :
In case of parts generated by LS Model of IBA format the user must indicate the Part of thefile and the Part library
In case of parts generated by Modaris of MDL format the user must fill in the Part name and specify the variant name and the Model file to which the part is linked, and the Model library.
In case of a mixed configuration of IBA/MDL format which allows to plot the parts generated by LS Model and Modaris, a toggle button Piece file/Piece name allows to switch from one case to another.
For Plotting files Markers:
Instead of parts produced by LS Type of PLA & IBA formats the user should show the Marker file the Marker library & the Part library
Instead of the parts are produced by Modaris of PLX & Mdl file formats the user should show the Marker file the Marker library & the Type library
Instead of a mixed configuration of PLA or PLX & IBA or Mdl file formats the user should show the Marker file , the Marker library & the Part library or the Type library
Vigiprint of Lectra Kaledo For Plotting Garments:
Instead of the parts produced by LS Type of PLA & IBA formats the user should show the Garment file, the Garment library & the Part library
Instead of the parts produced by the Modaris of PLX & Mdl file formats the user can plot a Type or a Variant. The choice is made in a pull-down menu. For a type he must fill in the name of the Type & the Type library, for a variant the Variant name the name of the associated Type file & the Type library
Instead of a mixed configuration of PLA or PLX & IBA or Mdl file formats the user can also plot garments. This function appears in the pull down menu. The user should then fill in the Garment name, the Garment library & the Piece library in Lectra vigiprint of Lectra Kaledo Modules
When the DVD of ModarisV5R1 is inserted in the PC an Autorun file will be executed that automatically open a folder. The man who will install can flow the setup guide in his chosen language. It describes the Modaris pattern software installation process and associated recommendations. It includes a ModarisV5R1 c3.exe file to directly pilot an automatic Modaris installation. A lot of applications installed by the Modaris installer. And includes another button Update Lectra workstation to allow upgrading other CAD workstations. Installation procedure of ModarisV7R2 is easier than Modaris V5R1
We have largest Garment and Textile ERP software collections in Bangladesh. We sale customized ERP for the factories. We are agent of all Garment and Textile ERP software company. We will forward you to the best ERP software company based on your requirements. We are trouble shooter of fashion industrial software like Willcom, Barudan, Lectra, How to install Lectra Plotter I Manager Software, Gerber, iEcho, Datacolor, Shedomaster, Batch, Qc etc. Email: autogarments@gmail.com, Cell: +88 017 92 52 53 54
How to install ModarisV5R1 Pattern Making Software:
First insert the Lectra CD into CDRom
Then go to the Lectra pattern making software Folder
Then click ModarisV5R1 .exe file
Then click Run Button to run the software
Then click Next Button for progressing the software
Then chose option button and click the I accept the terms of license agreement.
Then chose again option Typical or Custom. Generally select the Typical option. If you select you can install module by module according to your requirements
Then click again Next button again
Then click Finish Button. Now Your ModarisV5R1 pattern making modules installation is finished.
Update into Modaris V7R2:
The update procedure and location is described here shortly.
ModarisV7R2 Installer :
Modaris Installe provides an easy installation mode. This automatic Modaris installer file accessible from the setup guide that allows deploying required packages with one unique installer.
Pattern Making Software Free Modules:
After installing modaris v7r2 it will install more pattern making software free modules
Modaris: It is lectra pattern making software.
3D Prototyping: Lectra 3D Prototyping software.
Modaservice: Lectra service for Modaris data exchange.
JustPrint: Lectra plotting software.
E-Manager: It is another module of lectra
FLEXlm: It is another module of lectra
ButtonBox and Digitizer: These 2 modules are processed only when they are already deployed on the station
Upgrader:
The next automatic installer called Upgrader that is reachable through the Setup Guide. This upgrader is dedicated for all computers that are not Modaris stations. This upgrader need to be executed on CAD workstations used for plotting . This will ensure compatibility with applications installed by Modaris installer. It upgrades the following packages only if a previous release is already installed on the station.
Upgraded Free Pattern Making Doftware by Upgrader:
When ModarisV7R2 will upgrade it also generate some free pattern making software modules.
Modaservice: Lectra service unit to Modaris data exchange
XChang: Lectra software dedicated to Dxf data import in VigiPrint
Using Modaris installer and Upgrader apart from DVD:
At first copy all the installer folder tree from the DVD for guarantee a good deployment of Modaris installer and its modules. The following picture show within the red rectangle to the complete installer folder. After that execute Modaris installer that is running the following program: Packages\ModarisVxRy.exe or execute the Upgrader, running the following program: Packages\Related_Packages\Upgrader.exe
Installation Location:
By default, the installation folder is C:\Program Files\Lectra. To define a specific installation folder, for example: MY_INSTALLPATH, the command line will be: Package.exe■/v”INSTALLDIR=\”MY_INSTALLPATH\””
Note: “■” means a space character, “Package.exe” represents the package to install, “/v” is the option for defining parameters, “INSTALLDIR” is the MSI Value to define with the specific installation folder, Be careful to respect quotes””.
Example :
To install Modaris in following folder: “D:\ProgramFiles\Fashion_Solution”. The command line will be like this -Packages\ModarisVxRy.exe■/v”INSTALLDIR=\”D:\ProgramFiles\Fashion_Solution\””
To escape any dialog box requesting for a reboot you need to add the option “norestart” as shown in following command line: Package.exe■/v/norestart
Note: “■” means a space character and “Package.exe” represents the package to install and “/v” is the option for defining parameters, “/norestart” is the argument for avoiding reboot. The reboot prompt at the end of the Modaris Suite Installer deployment is due to a MSI Engine deployment. If MSI engine is not installed on the Operating System then it will be deployed by Lectra applications installation.
The concatenation of these options gives the following command line Package.exe■/v”/norestart■INSTALLDIR=\”MY_INSTALLPATH\””
Note: “■” means a space character where “Package.exe” represents the package to install and “/v” is the option for defining parameters. Always be careful to respect quotes””.
Example :
To install Modaris in following folder: “D:\ProgramFiles\Fashion_Solution”. The command line is:
Lectra Pattern Making Software Custom Installation:
Modaris installer and upgrader are the standard of Lectra software packages. They run stand alone packages normaly.If anybody want to create your own software scripts, it is mandatory to use the following stand alone packages instead of Modaris installer or upgrader. Here below the packages list of lectra pattern making software, the applications they install and their location on the DVD.
Modaris Software Evolution:
Modaris software evolution gives you access to the latest releases of Lectra solutions, allowing you to continually improve your technical performance and to optimize your best pattern design environment with each technological innovation. Modaris software evolution protects your investment over the long term. It makes savings while enabling you to maintain state of the art technology and systems.
Lectra Remote Expertise:
Lectra remote expertise offer global access to the experts and technical specialists via Lectra international call centers situated in Atlanta, USA (for North America); Bordeaux, France (for Europe); Madrid, Spain; Milan, Italy; and Shanghai, China (for Asia). The software as well as hardware can be accessed remotely by Lectra teams to provide real time IT solution for software problems production needs and workflow processes.
Lectra Consultation:
Lectra consultation services help you to identify difficulties related with your business as well as define environment for change in order to boost the creation of your products and reduce their time to market. The lectra teams of specialists will help you define priorities in terms of investments and prepare an action plan to speed up time to market, reduce costs, eliminate useless tasks and improve communication flows. On average, the lectrea specialists have more than 11 years of experience in garments and textile industry and in technology, which enables them to operate in each area of the consulting process, from audit to project implementation.
Training for Lectra Pattern Making Software :
Lectra provide training packages on lectra pattern making software you that will make optimal use of your software and equipment and will learn in record time. With more than 120 instructors, this training can be provided on site with customized programs or at one of Lectra training centers throughout the world. Chose the training modules best suited to your needs and combine them to create your own customized training program
Before installing Lectra Diamino you should Install Lectra Modaris V7R2 pattern module software. This document is the installation roadmap for the current version of Lectra Diamino Fashion V6R1 and its components. Lectra recommend you to read it in full and print it so that you have it to hand during the installation process. To use Lectra Diamino Fashion V6R1, you must have the FLEXlm licenses for the use of the software. If you do not have these licenses, please contact Lectra to obtain them. To know more about Flexlm license installation, read the FLEXlm Setup Guidedocument (PDF format). The Diamino Fashion workstations should meet the following prerequisites hardware requirments: Central processing unit –CPU – 2.8 Ghz, RAM for Windows 7 Enterprise 32-bit & 64-bit- minimum 2Gb and optimum 3Gb, RAM for Windows Vista Enterprise 32-bit & 64-bit (SP1,SP2) et Windows Vista Business 32-bit & 64-bit (SP1,SP2)- – minimum 2Gb and optimum 3Gb, RAM for Windows XP Professional 32-bit Edition (SP2, SP3) – minimum 2Gb and optimum 3Gb, HDD free space- 0,9 Go for installation of application and components
We are the largest Garment and Textile ERP software collector in Bangladesh. We sale customized ERP for the factories. We are sole agent of all Garment and Textile ERP Software companies. We will forward you to the best ERP software company based on your requirements. We are trouble shooter of fashion industrial software like Willcom, Barudan, Lectra, Lectra Plotter I Manager Software Install, Gerber, iEcho, Datacolor, Shedomaster, Batch, Qc etc. Email: autogarments@gmail.com, Cell: +88 017 92 52 53 54
Uninstall The Previous Version of JustPrint:
Having JustPrint V2R2 and a previous version of JustPrint installed on the same workstation is not recommended. Before installing, uninstall the previous version of JustPrint (V1R1, V2R1 or V2R2):
Start a Windows session using an administrator account or a user account with administrator rights.
Go to Start->Settings->Control Panel and launch “Add or Remove Programs”.
In the “Currently installed programs” list, select the previous version of JustPrint, click on “Change/Remove” and follow the instructions
Applications of Lectra Diamino:
All necessary components will be installed if missing or updated to the latest version :
DiaminoFashion V6R1
Xchang V3R5
ButtonBox V1.1
Modaservice V7R1
JustPrint V2R2
Installation Procedure of Lectra Diamino Modaris V6r1 :
At first Exit all running applications to install Modaris V6r1
Open a Windows session with Administrator account or a admin user account with administrator rights.
Then click on the Diamino Fashion Installation
Then select Open or Run in the next window.
Select Run or Continue in the next window.
Click on Install to install the prerequisites.
Allow the workstation to prepare for installation (“Preparing to install…”)
Then click on Next in the first DiaminoFashion V6R1 Installer window.
Select I accept the terms of the license agreement
After that click on Next.
Then A window will appears offering to install your license files
If you have received your licenses:Check Install License Files,
If you have license in folder then the installation looks for the files on the desktop of the current user. If the license files are in a different folder, click on Browse to select the folder containing the license files, then on OK, Click Next,
Select Complete
Then click on Next
After that click on Install. The installation procedure may take a few minutes.
Installation may end with a dialog box asking if you want to restart your computer. We recommend that you select Yes to restart.
Finally click on “Finish“.
Configuration Other Lectra Workstations:
The other Lectra workstations where you use a Lectra application other than DiaminoFashion must be updated with the latest versions of Modaris V6r1 and XChang. Procedure of other Lectra workstations is given below:
First exit all running application software.
Then open a Windows session with administrator account or a admin user account with administrator rights.
First Insert the CD into CDRom
Then click on the “Update” button below
After that select “Open” or “Run” of the next window.
Then Select “Run” or “Continue” of the next window.
Then click on “Next” and “Install” in each window.
Supported Operating Systems for Diamino Modaris V6r1 :
Windows XP Professional (Service Pack 2, Service Pack 3)
Windows Vista Enterprise 32-bit & 64-bit Edition (Service Pack 1, Service Pack 2)
Windows Vista Business 32-bit & 64-bit Edition (Service Pack 1, Service Pack 2)
Windows 7 Enterprise 32-bit & 64-bit Edition
Licenses for Lectra Diamino Marker Making Software:
If you need any help please contact me in below mobile number. If you did not install the license files of DiaminoFashion marker making software and its components, you must install them onto your workstation when you receive them. For licence please visit For doing this, click on the ” Install license files ” button below and follow the procedure.
At first select Yes or Run when you are asked for confirmation.
Than select Browse for selecting the folder containing the license files,
Then click on Copy Files.
A message tells you how many license files were found in the folder and copied.
Finally click on OK to run marker making software.