What is 3Kva UPS ? General UPS Functionality
3Kva UPS – Read about General Guidelines for UPS
outr power capacity | 2.7 KWatts / 3.0 kVA | |
KW Configurable Power (watts | 2.7 KWatts / 3.0 kVA | |
P•vinal Output Voltage | 230V | |
OtraVoltage Note | Configurable for 220: 230 or 240 nominal output voltage | |
Output Voltage Distortion | Less than 3% | |
Output Frequency (sync to mains) | 50/60Hz •1- 3 Hz | |
Load Crest Factor | 3:01 | |
Topology | Double Conversion Online | |
Waveform type | Sine wave | |
Output Connections |
(8) IEC
320 C13 (Battery Backup) (2) IEC Jumpers (Satiety Backup) (21 IEC 320 C19 (Battery Backup) | |
Bypass | Internal Bypass (Automatic and Manual) | |
Input | ||
Nominal Input Voltage | 230V | |
Input frequency | 40 – 70 Hz (auto sensing) | |
Input Connections | British 651363A, IEC-320 C20, Schuko CEE 7/EU1-I6P | |
Input voltage range for main operations | 160 – 275V | |
Input voltage adjustable range for mains operation | 100.275 (half load)V | |
Cord Length | 2.44meters | |
Other input voltages | 220, 240 | |
Number of Power Cords | 3 | |
Communications & Management | ||
Interface Port(s) | R1-45 Serial , Smart-Slot , USB | |
Control panel | Multi-function LCD status and control console | |
Audible Alarm | Audible and visible alarms prioritized by severity | |
Emergency Power Off (CPO) | yes | |
Surge Protection and Filtering | ||
Surge energy rating | 340Joules | |
Filtering | 340Joules | |
Featu es & Benefits | ||
Embedded network management card with environmental monitoring (5 kVA — 10 kVA models) | Remote monitoring and control of the UPS and the environment via Ethernet connection while freeing up the SmartSlotTM so customers can add accessories for additional communication options. | |
Display | LCD Display | |
Operate without battery | Yes |
Sendon UPS functionality:
- Switch on your Sendon UPS. The ON/OFF Led should be Green. The green LED indicates that the voltage is normal. So you can operate your computer system as usual.
- When the red LED remains ON for a few seconds and then turn off, it means the internal control circuit has shutdown. It is necessary to turn off the POWER switch for at least 6 seconds to reset this condition. Also check whether the UPS is overloaded or short circuited.
- Both the red LED and biff are on intermittently as long as the UPS is in back-up mode.
- When the battery charge is finished, the UPS will shutdown itself. The red LED and biff will be on for a few seconds and then turn OFF.
Micro UPS Functionality:
There is three LED in the front of this UPS
- AC Normal
- Inverter
- Charging
AC Normal: When the computer is run from AC via UPS this LED is ON
Inverter: When electricity is not available then the computer is run from battery /Inverter mode. On that time this LED is ON.
Charging: When battery will be charging this LED will be on. The benefit of micro UPS is when you leave office you must switch off your UPS. As a result instead of switch OFF of the UPS, it will be charging during your leaving time.
You can contact me to understand in detail.
More Equipment
• Automatic Voltage Stabilizer
• – Domestic and Industrial ( 1KVA to 5MVA)
• Uninterruptible Power Supply (UPS)
• ( On-Line UPS & Off Line UPS)
• – Domestic and Industrial
• Emergency Power Supply (IPS / EPS)
• Sub-Station Equipment
• – 5KVA to 5MVA
• Automatic Battery Charger
• Converter & Rectifier
• Digital Clock
• Distribution Transformer
• – 5KVA to 5MVA
• Static Inverter
• PFI Plant
• Water Level Controller (WLC)
• Electronic Fan Regulator (EFR)
• Electronic Ballast
• Electronic Moving Message Display
• Other Electronic Equipment
• Fire Hydrant System
• CC camera System
• CC camera Central monitoring System
• Building Management And Controlling System (BMC)
Trackbacks/Pingbacks