Audit Report of a Washing Factory

Audit Report of a Washing Factory

A security audit was carried out at Auto  Washing Ltd on 15 August 2009

Personal Security.

  • Physical Security.
  • Information Access Control.
  • Storage and Distribution.
  • Contractor Control.
  • Drug Interdiction.

The audit team consisted of the following persons of Corporate Head Office.

The audit started at 1015 hrs and concluded at 1700 hrs. The following are the observations:

Personal Security

  • Some lefty workers ID copy not displayed in the main gate.
  • Security Awareness among the workers needs to be geared up.
  • Background checks of old workers are not up dated frequently.
  • 9 New Workers were found not issued with IDs.
  • Employment history checks are not conducted correctly.
  • Background checks are not completed for some new workers.
  • The plant has some isolated security related policies but missing a comprehensive Security Policy contained in a single book.
  • Missing ID card cases not investigated properly.

Physical Security

  • The tree situated between the perimeter wall and the factory building should be covered with barbed wire.
  • Chassis number of incoming cargo Covered Van not recorded in the Vehicle In/Out Register.
  • Some lights were found fuse near the perimeter wall.
  • There are no distribution records of keys.
  • Phone number of nearest Police Station not displayed with other important number in the gate.
  • Parking lot is not properly monitored.
  • Back ground checks on all applicants are not documented.
  • CCTV monitor recording is of 32 days only.
  • Auto intrusion detection system not yet installed in the factory.
  • Guards on patrol duty are not provided with torch lights at night.
  • Training and awareness on Cargo Integrity, recognition and detection of dangerous substances, internal conspiracies etc are to incorporated in the training classes.
  • Restriction on employees’ access must be restricted to own relevant areas.
  • Some portion of perimeter wall needs more lights to illuminate during hours of darkness.
  • Parking Lot for visitors and employees not separated.
  • Internal patrolling of guards is not documented in Guards Patrol Register.

Information Access Control

  • Computer back up system is not stored properly.
  • Incidents of unauthorized IT system access are not investigated.
  • Invalid password attempt to access file is not reviewed periodically.
  • Information access related security and procedures are not documented and verifiable.
  • The facility should implement intrusion warning system into its network system.
  • Factory must possess a policy for disciplining IT system violators.

Storage and Distribution

  • Cargo units are labeled but not weighed before loading.
  • Storage and distribution security procedures need improvements.
  • Restriction of movement of uninvolved persons in the loading dock.
  • There is no security control system in place to prevent introduction of foreign materials at the point of loading.
  • The sentry on duty at the store area needs to be trained further on counter intruder procedure.
  • Partially loaded cargo vans are not sealed.
  • Contractor Control
  • Security related aspects are not incorporated in the agreement.
  • Contractors records which are not documented in a separate register.
  • While selecting contractor the facility does not consider contractor’s security control.
  • Contractors back ground checks are not made.

About Engr Kh Mashiur Rahman

He is Top Class Digital Marketing Expert in bd based on Google Yahoo Alexa Moz analytics reports. He is certified IT Professional from Aptech, NCC, New Horizons & Post Graduated from London Metropolitan University (External) in ICT . To Hire his service and Him make a comment in below of any articles, Cell# +880 1792525354