DM Water and Mineral Water Plant            

DM Water and Mineral Water Plant Main power supply

  1. Inspection for voltage fluctuation
    1. Proper earthing condition
    2. Inspection for damage of contact point
    3. Check the indicator lamp damage or not
    4. Check proper functioning all the switch aaa
      Feed water pump
  2. Check water leakage
    1. Check electrical connection
    2. Check any abnormal sound
    3. Check the current, voltage
    4. Check the motor hot or cool at running condition
      Filter
  3. Clean the filter housing
    1. Replace all micron filter
    2. Any damage of the gasket
      Purge pump
  4. Is the purging accepted limit
    1. Any abnormal sounding at running condition
    2. Check the valve is proper functioning
    3. Check any leakage
    4. Check electrical connection
    5. Check the current and voltage
    6. Check the motor hot or cool at running condition
      UV Lamp
  5. The lamp is OK or not
    1. Check the lamp is properly connected
    2. Proper cleaning
      Break Tank
  6. Clean the tank
    RO membrane
  7. Check the direction of water circulation
    1. Any water leakage
      Pressure Switch
  8. Check the functioning of pressure switch
    1. Check the set point of pressure range is correct
      NAOH dosing tank with pump
  9. Any leakage at the pump
    1. Any abnormal sounding at running condition
    2. Check the electric connection
    3. Proper cleaning

Brime measuring tank

  1. Clean the tank Saocl dosing tank with pump 1. Any leakage at the pump
    1. Any abnormal sounding at running condition
    2. Check the electric connection
    3. Proper cleaning

Controlling valve

  1. Any leakage at the valve
    1. Is the valve operated easily

Pressure gauge

  1. Correct Indication
    1. External cleaning
    2. Any leakage at the connecting point

Storage tank

  1. Check the functioning of strainer
    1. Check the water heater damage or not
    2. Any water leakage at the setting point of heater
    3. Change the jacket water
    4. Check the current and voltage of electric motor
    5. Any abnormal sound at the electric motor
    6. Proper Cleaning the tank

Chemical

  1. Check present stock of the require chemical

Cleaning

  1. Overall surfaces in the panel board, MCB, MC
    1. Outer surface of electric motor and all parts
    2. Painted the rusted surface area