Fire Detection Equipment

  • Labeling: will ensure Fire Detection within 6 months   …We have shown to you our latest labeling, MSDS & APEO free certificate. But it is not fulfill your requirement. So we talked to chemical supplier. They took six months time from us to develop their system.
  • MSDS: will ensure within 6 months
  • Chemical Certificate: will ensure within 6 months
  • Chemical Monitoring Sheet: will ensure within 6 months We have already submitted the sheet without filling the “Cas No.” In our MSDS we couldn’t find any cas no.We talked to chemical supplier about the cas no. and they will provide the cas no. to us within 06 months.
  • EHS Self-Assessment: will ensure within 6 months for After successfully ETP & chemical related issues then we have completed the EHS Self Assessment
  • Water Production Data: will ensure within 6 months for Due to Some technical problems of water pipe lines it will take time to install flow water in the production unit. That’s why we are unable to fill up the water production data accurately.
  • Water Flow Meter Installation (1. Inlet of whole premises/factory 2. Inlet of washing/ dyeing /printing 3. Outlet of ETP) : will ensure within 6 months for

Due to some technical problems of water pipe lines it will take time to install flow water in the

Whole premises (Inlet). Washing (Inlet).

  1. Rest of Construction:  04 Months,
  2. Machineries Installation:  01 Month,
  3. Commission’s & test Run:  01
  • Waste water test Report of ETP Inlet & outlet: will ensure within 6 months for

After Successfully operation of ETP, we can collect the test Report of waste water.

Fire:

  • What has been your main learning from the day?

We learned details of Fire Safety Management System & its advantage.

  • What do you think is your way forward after the meeting?

This meeting provides us a massage how to improve our present fire safety position and need to follow up fire necessary check list related to fire safety issue regularly.

  • Do you think there is a need for regular assessment of fire and electrical? If yes, how do you think this would help you to improve?

Yes.

  • Schedule maintenance of Fire Detection Equipment will make us know the condition of fire fighting equipment.
  • Schedule maintenance of electrical system will make us free from Risk of fire.
  • Do you know who to turn to in case of the above assessments?

Firstly fire safety officer will lead the team in association with compliance & maintenance department.

  • Do you follow management system for checking the fire safety? What is the score of MS on 27 S?

Yes. Properly & our MS score is 19 on 27.

Mainly there are two types of Fire Detection Equipment:

Fixed Fire fighting equipment:

Hose pipe/Hose reels, Fire pump. Fire alarm,Exit sign. PA system. Emergency light.

Portable Fire Detection Equipment:

Fire extinguisher, Fire blankets, Gas mask, Water buckets, Fire beater, Fire hook,  Stretcher, Helmet. Gum boot, Torch light, Menila rope, Hand gloves and Lock cutter.

Fire Extinguisher:

DCP (Dry chemical powder )Fire Extinguisher  2) CO2 Gas (C arbon di-oxide ) Fire extinguisher  3) Foam type Fire extinguisher  4) Water type  fire extinguisher.

USE OF FIRE EXTINGUISHER

Always use suitable extinguisher

DCP fire extinguisher – Use at A,B,C & E types fire

CO2 fire extinguisher – Use at E types fire.

FOAM type fire extinguisher – Use at B types fire

WATER type fire extinguisher – Use at A & D types fire

Local Supplier                    : Symantec Technology Ltd

Supplier address              : 20/5, West Panthapath, Dhanmondi, Dhaka.

Equipment NameIdentification

 

Number

ManufacturerCertification

 

Authority

Model NoCertification

 

license number

Fire Alarm Control PanelSYNCRO DS1jj6(Series-6000)KM73505Kentec Electronic Ltd,UKkitemark
Smoke DetectorA10oio00G21300JHJ8,928b/02Argus Security, ItalyVds,LPCB
Heat DetectorA350JHJ0G21300JHJ9,928a/02Argus Security, ItalyVds,LPCB
Multi Sensor DetectorA350HJHJ0G21300HJH7,928c/02Argus Security, ItalyVds,LPCB
Beam Detectorthe fire beamG206HJHJ056The fire beamVds
Air Sampling DeviceN/A   
Control/Monitor ModuleVMC12JJH0G212JHJ029Argus Security, ItalyVds
Horn/ Horn With StrobeFulleon,RPLP SVG206JHJ019-2EatonVds
Manual Call Point/Manual Pull StationVCP100928hJH/01Argus Security, ItalyLPCB
Cable1.5,2JH.5(FPS-215HJHER,FPS-225ERJHJ), TJ-1502XJHJ,TJ-2502X682HJHJHe/01, E464899Context Plus,UK,Tianjie,ChinaLPCB,UL
Others    
LOCUTION Fire Detection EquipmentNameManufacturerCertification

 

Authority

Remark

 

(Mention Diameter)

PIMP ROOM65 MM LANDING VALVENAFCOLPCB 463e/01 
PIMP ROOM40 MM LANDING VALVE   
PIMP ROOMALARM CHECK VALVE   
(AKL) FIRE HOSE PIPE LIST30 METER LONG FIRE HOSENAFCOUL LISTED1 ½” DIAMETER.
GROUND FLOORCENTRAL STORE BOX NO-(9)NAFCOUL LISTED1 ½” DIAMETER.
SEWING FLOOR – 1 NO.  STAIR INDIDE BOX NO-(2)NAFCOUL LISTED1 ½” DIAMETER.
TOILET SIDE BOX NO-(3)NAFCOUL LISTED1 ½” DIAMETER.
SEWING FLOOR – 2 NO. STAIR INDIDE BOX NO-(4)NAFCOUL LISTED1 ½” DIAMETER.
FEBRIC STORE – 3 NO.  STAIR INDIDE BOX NO-(6)NAFCOUL LISTED1 ½” DIAMETER.
FEBRIC STORE – 3 NO. STAIR INDIDE BOX NO-(7)NAFCOUL LISTED1 ½” DIAMETER.
FEBRIC GOODS-(01)MAIN EXIT OUTSIDE BOX NO-50NAFCOUL LISTED1 ½” DIAMETER.
2ND  EXIT INSIDE BOX NO-53NAFCOUL LISTED1 ½” DIAMETER.
FEBRIC GOODS-(02)MAIN EXIT INSIDE BOX NO-48NAFCOUL LISTED1 ½” DIAMETER.
 MIDEL OF GOWDON BOX NO-49NAFCOUL LISTED1 ½” DIAMETER.
1ST FLOOR4 NO STAIR INSIDE BOX NO-(15)NAFCOUL LISTED1 ½” DIAMETER.
1  NO STAIR INSIDE BOX NO-(10)NAFCOUL LISTED1 ½” DIAMETER.
TOILET SIDE BOX NO-(12)NAFCOUL LISTED1 ½” DIAMETER.
LocutionEquipment NameIdentification

 

Number

ManufacturerCertification

 

Authority

GROUND. ASSEMBILEY POIENTFIRE PUMP

 

SET

AMOTOR DRIVEN PUMPBVBARMSTRONGFM APPROVED UL LISTED
BDIESEL ENGINE DRIVEN PUMPVBVARMSTRONGFM APPROVED UL LISTED
CJOCKEY PUMPVBVARMSTRONGFM APPROVED UL LISTED
MAIN GETFIRE RIGADE CONNECTION ( 4 ) WAYNVBVBNAFCOUL LISTED
BACK GETFIRE RIGADE CONNECTION ( 2 ) WAYNBI 11VBVB5,SL 10/14NAFCOUL LISTED
PIMP ROOMNON RETURN VALVE   
PIMP ROOMOS & Y GATE VALVEHTZoVBVBoCHINA 
PIMP ROOMY- STRAINERAVBVRICHINA 
PIMP ROOMFLEXIBLE JOINT CHINA 
PIMP ROOMPRESSURE RELIEF VALVE   
PIMP ROOMBUTTERFLY VALVE WITH SUPERVISORYXJ23FGVxCHINA 
PIMP ROOMTEST & DRAIN VLAVENDFGFGR 098NAFCO 
PIMP ROOMSPRINKLER HEADN/FGFAN/AN/A
PIMP ROOMPIPE (ASTM A53 SCH40 OR BS 1387 CLASS B )   
PIMP ROOMPRESSURE GAUGECHINAFGF  
PIMP ROOMPRESSURE SWITCH   
PIMP ROOMPILLAR HYDRANT ( 2) WAYNHYDFGFG 060NAFCO 

Conclusion

Note: Please attach the necessary documents such as certificate, testing reports, picture etc. with this Fire Detection Equipment checklist.